SSH Electric Steam Superheater: Specifications
SSH Electric Steam Superheater: Specifications
The following chart gives guidelines to properly select a Sussman Series SSH steam superheater for your application. Specify voltage / phase / hertz. Contact factory for additional sizing guidelines
GAUGE PRESSURE (PSIG) | REQUIRED BTU'S PER LB. OF STEAM TO REACH FINAL TEMPERATURE OF: | |||||
---|---|---|---|---|---|---|
300°F | 400°F | 450°F | 500°F | 600°F | 700°F | |
15 | 152 | 193 | 223 | 253 | 314 | 374 |
25 | 144 | 206 | 236 | 266 | 327 | 387 |
35 | 136 | 197 | 227 | 257 | 318 | 378 |
45 | 131 | 192 | 222 | 252 | 313 | 373 |
55 | - | 188 | 218 | 248 | 309 | 369 |
65 | - | 181 | 211 | 241 | 303 | 363 |
75 | - | 179 | 209 | 239 | 301 | 361 |
85 | - | 176 | 206 | 236 | 297 | 357 |
95 | - | 174 | 204 | 234 | 295 | 355 |
105 | - | 171 | 201 | 231 | 292 | 352 |
115 | - | 169 | 199 | 229 | 290 | 350 |
125 | - | 168 | 198 | 228 | 289 | 349 |
135 | - | 168 | 198 | 228 | 289 | 349 |
145 | - | 162 | 192 | 222 | 284 | 344 |
155 | - | 161 | 191 | 221 | 282 | 342 |
165 | - | 160 | 190 | 220 | 281 | 341 |
175 | - | 161 | 191 | 221 | 282 | 342 |
185 | - | 159 | 189 | 219 | 280 | 340 |
195 | - | 156 | 186 | 216 | 277 | 337 |
205 | - | 159 | 189 | 219 | 280 | 340 |
215 | - | 159 | 189 | 219 | 280 | 340 |
225 | - | 155 | 185 | 215 | 276 | 336 |
235 | - | 151 | 181 | 211 | 272 | 332 |
245 | - | 149 | 179 | 209 | 270 | 330 |
255 | - | 149 | 179 | 209 | 270 | 330 |